Abstract :
Osteoporosis results in high fracture risks of vertebral bone. A considerable amount of work has been done to investigate the biomechanical characteristics of osteoporotic vertebral trabecular bone. Previous researchers studied the elastic characteristics using a micro-finite element (micro-FE) model, used to analyze realistic trabecular architectures in full detail, based on micro-computed tomography (muCT). Since osteoporotic compression fracture is closely associated with the mechanical characteristics of the vertebral trabecular bone and there were few micro-FE models to account for all of the elastic and plastic characteristics in vertebral trabecular bone, this study analyzed the effect of voxel resolution on the plastic as well as the elastic characteristics of three-dimensional (3D) osteoporotic lumbar trabecular bone models. Also, we evaluated the effect of specimen size on this problem. It has been reported that a cubic specimen with side length 6.5 mm was suggested as standard specimens for the experimental test of trabecular bone. Current study examined whether or not the effect of the specimen geometry on the experimental test may be also applied to the simulated compression test of trabecular bone specimens. The experimental test employing the rapid prototyping (RP) technique and INSTRON test machine is performed to indirectly validate the results of the simulated compression test by micro-FE analysis. The review finished with the verification about the effects of the simulated compression test.
Keywords :
biomechanics; bone; compressive testing; computerised tomography; diagnostic radiography; diseases; finite element analysis; fracture; 3D osteoporotic bone model; INSTRON test machine; biomechanical test; elastic characteristics; finite element analysis; microCT; osteoporotic compression fracture; osteoporotic vertebral trabecular bone; plastic characteristics; rapid prototyping technique; simulated compression test; size 6.5 mm; specimen geometry;
Conference_Titel :
Biomedical and Pharmaceutical Engineering, 2006. ICBPE 2006. International Conference on
Conference_Location :
Singapore
Print_ISBN :
978-981-05-79
Electronic_ISBN :
81-904262-1-4