DocumentCode :
462098
Title :
Application of Self-Assembled Monolayer of Carboxy-1-Decanthiol for Cholesterol Biosensor
Author :
Solanki, Pratima R. ; Arya, Sunil K. ; Malhotra, B.D. ; Nishimura, Y. ; Iwamoto, M.
Author_Institution :
Nat. Phys. Lab., New Delhi
fYear :
2006
fDate :
11-14 Dec. 2006
Firstpage :
393
Lastpage :
396
Abstract :
Cholesterol oxidase was immobilized on the 10-Carboxy-1-decanethiol (CDT) self assemble monolayer prepared on the gold (Au) substrate. These electrodes have been characterized using contact angle (CA) measurements, electrochemical techniques and atomic force microscopy (AFM). These ChOx/CDT/Au electrodes have been utilized for the estimation of cholesterol concentration in solution using the surface plasmon resonance (SPR) technique.
Keywords :
atomic force microscopy; biosensors; electrochemical electrodes; gold; monolayers; organic compounds; self-assembly; surface plasmon resonance; AFM; Au; ChOx-CDT-Au electrodes; SPR technique; atomic force microscopy; carboxy-1-decanthiol; cholesterol biosensor; cholesterol concentration estimation; cholesterol oxidase; contact angle measurements; electrochemical techniques; gold substrate; self assembled monolayer; surface plasmon resonance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical and Pharmaceutical Engineering, 2006. ICBPE 2006. International Conference on
Conference_Location :
Singapore
Print_ISBN :
978-981-05-79
Electronic_ISBN :
81-904262-1-4
Type :
conf
Filename :
4155930
Link To Document :
بازگشت