DocumentCode :
462339
Title :
A High Precision Peak Detect Sample and Hold Circuit
Author :
Chang, P.Y. ; Chou, H.P.
Author_Institution :
Dept. of Eng. & Syst. Sci., National Tsing Hua Univ., Hsinchu
Volume :
1
fYear :
2006
fDate :
Oct. 29 2006-Nov. 1 2006
Firstpage :
329
Lastpage :
331
Abstract :
The paper presents a high precision peak detect sample and hold (PDSH) circuit for nuclear radiation spectroscopy. A small compensation current source is applied to reduce the measuring error and improve the resolution. For nuclear pulses with the peak value ranging from 0.1 to 1 volts with a frequency about 100 kHz, test results showed that voltage drop is 2.16muV/mus and the voltage error is less than 0.5 mV.
Keywords :
nuclear electronics; peak detectors; sample and hold circuits; high precision peak detect sample and hold circuit; nuclear pulses; nuclear radiation spectroscopy; CMOS technology; Capacitors; Circuit testing; Diodes; Mirrors; Modems; Radiation detectors; Spectroscopy; Temperature dependence; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.356168
Filename :
4179007
Link To Document :
بازگشت