DocumentCode :
462595
Title :
Development of MRI-Compatible Nuclear Medicine Imaging Detectors
Author :
Wagenaar, D.J. ; Nalcioglu, O. ; Muftuler, L.T. ; Szawlowski, M. ; Kapusta, M. ; Pavlov, N. ; Meier, D. ; Maehlum, G. ; Patt, B.E.
Author_Institution :
Gamma Medica-Ideas Inc., Northridge, CA
Volume :
3
fYear :
2006
fDate :
Oct. 29 2006-Nov. 1 2006
Firstpage :
1825
Lastpage :
1828
Abstract :
The value of pre-clinical PET and MRI is established, and SPECT also is now routinely used in drug development, disease treatment, and molecular biology research. The aim of this research is to prepare and test imaging prototypes of both SPECT and PET with similar form-factors for use within the core of a pre-clinical MRI. To test the imaging properties of the SPECT detector in a magnetic field a prototype based on CZT semiconductor detectors has been fabricated. This detector has a field-of-view of 2.54 times 12.7 cm2 and is fitted with a parallel hole collimator for mouse imaging. The prototype is designed to obtain a tomographic dataset by manual positioning within a 90-degree projection range. Shielding, support, positioning, and cooling materials were selected to minimally influence the magnetic field homogeneity. Fabrication of a stationary, polygonal ring of CZT has commenced. An APD-based, light-sharing detector has been evaluated for use in PET. The detector configuration is a 2 times 2 array of 10 mm times 10 mm Hamamatsu S8664-1010 APDs used to read out multi-crystal LYSO blocks. The design of the detector and front-end electronics is optimized for spectroscopic and timing performance, minimization of power dissipation, and low electromagnetic interference. Current plans are for assembling five rings, each with 17 modules, to give a 13.0 cm axial FOV with a 14 cm inner diameter. The results on the tests and performance of both types of modules are reported.
Keywords :
biomedical MRI; positron emission tomography; semiconductor counters; single photon emission computed tomography; CZT semiconductor detectors; CdZnTe; Hamamatsu S8664-1010 APD; PET detector; SPECT detector; detector configuration; disease treatment; drug development; electromagnetic interference; light-sharing detector; magnetic field homogeneity; manual positioning; molecular biology research; multicrystal LYSO block; nuclear medicine imaging detector; parallel hole collimator; power dissipation minimization; pre-clinical MRI; spectroscopic performance; timing performance; Detectors; Diseases; Drugs; Magnetic cores; Magnetic materials; Magnetic resonance imaging; Nuclear medicine; Positron emission tomography; Prototypes; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.354248
Filename :
4179361
Link To Document :
بازگشت