DocumentCode :
462638
Title :
18F-FDG PET images segmentation using morphological watershed: a phantom study
Author :
Tylski, Perrine ; Bonniaud, Guillaume ; Decenciere, Etienne ; Stawiaski, Jean ; Coulot, Jeremy ; Lefkopoulos, Dimitri ; Ricard, Marcel
Author_Institution :
Inst. Gustave Roussy, Villejuif
Volume :
4
fYear :
2006
fDate :
Oct. 29 2006-Nov. 1 2006
Firstpage :
2063
Lastpage :
2067
Abstract :
Segmentation of 18F-FDG PET images could be helpful for delineation of tumor volume in radiotherapy and patient follow-up. The most commonly implemented method on clinical workstations is maximum intensity thresholding, which is inappropriate for heterogeneous uptakes. Our aim was to develop and evaluate a more sophisticated segmentation method, based on the morphological watershed. We developed a segmentation method taking into account PET images characteristics. We evaluated it first on phantom images, using an integrated PET/CT unit and taking CT images as reference images. To simulate tumors in a background activity, we used 6 homogeneous spheres of various volumes in a cylindrical phantom and 3 heterogeneous cylinders in an anthropomorphic phantom. The quality of segmentation was evaluated in terms of volume, shape and position. We compared the results with a maximum intensity threshold segmentation method fitting the volume, taken as reference segmentation. A quantitation analysis completed the phantom study. For both phantom acquisitions, the segmentation obtained with the watershed based algorithm gave satisfying results with the index integrating volume, shape and position. Results considering this index were not significantly different from the reference segmentation (p > 0.5). Errors of volume recovery reached 18% for watershed segmentation. The quantitation analysis on phantoms highlighted partial volume effect, with an error of activity concentration measurement on segmented images ranging between 42% and 51%. Performances of the watershed method evaluated in this study were comparable with an optimized segmentation on phantom images. The quantitation recovery of PET regions with this method was similar with to other segmentation methods.
Keywords :
fluorine; image segmentation; medical image processing; organic compounds; phantoms; positron emission tomography; radiation therapy; radioisotope imaging; tumours; 18F; 18F-FDG PET; activity concentration measurement; anthropomorphic phantom; computerized tomography; fluoro 18 labelled fluorodeoxyglucose; image segmentation; integrated PET-CT unit; maximum intensity threshold segmentation method; morphological watershed; partial volume effect; phantoms; positron emission tomography; quantitation analysis; quantitation recovery; radiotherapy; segmentation quality; tumor volume delineation; Anthropomorphism; Computed tomography; Image analysis; Image segmentation; Imaging phantoms; Neoplasms; Positron emission tomography; Shape; Volume measurement; Workstations;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.354319
Filename :
4179433
Link To Document :
بازگشت