DocumentCode
466266
Title
Novel method for detection of transformer winding faults using Sweep Frequency Response Analysis
Author
Singh, Jaskirat ; Sood, Yog Raj ; Jarial, R.K.
Author_Institution
Dept. of Electr. Eng., NIT Hamirpur, Hamirpur
fYear
2007
fDate
24-28 June 2007
Firstpage
1
Lastpage
9
Abstract
Sweep frequency response analysis (SFRA) is an established tool for determining the core deformations, bulk winding movement relative to each other, open circuits and short circuit turns, residual magnetism, deformation within the main transformer winding, axial shift of winding etc. This test is carried out on the transformer without actual opening it and is an off line test. This paper explains the fundamental studies of SFRA measurement on basic electrical circuits, which can be extended for studying the mechanical integrity of a transformer after short circuit fault, transportation etc.
Keywords
fault diagnosis; frequency response; power transformer testing; transformer windings; SFRA measurement; bulk winding movement; core deformation; mechanical integrity; open circuit turns; residual magnetism; short circuit turns; sweep frequency response analysis; transformer winding deformation; transformer winding fault detection; Circuit faults; Circuit testing; Electrical fault detection; Fault detection; Frequency response; Magnetic analysis; Magnetic circuits; Magnetic cores; Transformer cores; Windings; Impulse response; Power Transformer; Resonance frequency; SFRA; Winding Deformation;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering Society General Meeting, 2007. IEEE
Conference_Location
Tampa, FL
ISSN
1932-5517
Print_ISBN
1-4244-1296-X
Electronic_ISBN
1932-5517
Type
conf
DOI
10.1109/PES.2007.385945
Filename
4275711