DocumentCode
468473
Title
The criterion on inter-turn short circuit fault diagnose of steam turbine generator rotor windings
Author
Li Yong-Gang ; Sun Yi ; Wang Lin-li ; Li Hai-Bo
Author_Institution
North China Electr. Power Univ., Beijing
fYear
2007
fDate
8-11 Oct. 2007
Firstpage
1050
Lastpage
1054
Abstract
In this paper, the cause and its serious hazard of the inter-turn short circuit fault on turbine generator rotor windings are analyzed. Furthermore the electromagnetic characteristics and mechanical characteristics as well as the correlative variety of the electrical parameters induced after inter-turn short circuit fault on turbine generator rotor windings are analyzed. Based on the fault characteristics that the excitation current increased while the reactive power output decreased relatively when the inter-turn short circuit happens, a fault characteristic mathematical model of inter-turn short circuit is founded considering the saturated situation of steam generators.
Keywords
fault diagnosis; mathematical analysis; reactive power; rotors; short-circuit currents; steam turbines; turbogenerators; electromagnetic characteristics; excitation current; interturn short circuit fault diagnosis; mathematical model; mechanical characteristics; reactive power; steam turbine generator rotor windings; Character generation; Circuit faults; Magnetic circuits; Magnetic flux; Magnetic forces; Mathematical model; Power generation; Reactive power; Rotors; Turbines;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems, 2007. ICEMS. International Conference on
Conference_Location
Seoul
Print_ISBN
978-89-86510-07-2
Electronic_ISBN
978-89-86510-07-2
Type
conf
Filename
4411964