DocumentCode :
468611
Title :
Four-quadrant drive control and signal conditioning of DC load motor for permanent magnetic machine testing
Author :
Cai, Zhongfa ; Chen, Longdao ; Fan, Weimin
Author_Institution :
Zhejiang Univ. Hangzhou, Hangzhou
fYear :
2007
fDate :
8-11 Oct. 2007
Firstpage :
1815
Lastpage :
1819
Abstract :
The permanent magnetic (PM) synchronous machine testing calls for high performance of the load motor drive control and signal conditioning. The traditional load drive control using motor-alternators cannot meet up with the requirements of the PM machine testing satisfactorily. The paper demonstrates a four-quadrant drive control of the dc load motor using a rectifier apparatus for the PM machine testing. In the proposed approach, the double closed-loop control implements the constant speed and constant torque loads for different testing items. The median filtering and moving average filtering further improve the reliability and accuracy of the testing system. The results have confirmed the correctness and validity of the proposed methods.
Keywords :
DC motors; alternators; closed loop systems; machine control; machine testing; permanent magnet motors; power system reliability; rectifiers; synchronous motors; DC load motor; closed-loop control; four-quadrant drive control; load drive control; median filtering; motor-alternators; permanent magnetic synchronous machine testing; rectifier apparatus; reliability; signal conditioning; AC motors; Acoustic testing; Control systems; DC motors; Motor drives; Permanent magnet motors; Rectifiers; Synchronous motors; System testing; Traction motors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2007. ICEMS. International Conference on
Conference_Location :
Seoul
Print_ISBN :
978-89-86510-07-2
Electronic_ISBN :
978-89-86510-07-2
Type :
conf
Filename :
4412102
Link To Document :
بازگشت