• DocumentCode
    468687
  • Title

    The characteristics of the total phase inductance and the angle gamma for salient pole synchronous machines

  • Author

    Dajaku, Gurakuq ; Gerling, Dieter

  • Author_Institution
    Univ. of Fed. Defense, Munich
  • fYear
    2007
  • fDate
    8-11 Oct. 2007
  • Firstpage
    719
  • Lastpage
    722
  • Abstract
    Deriving the correct formula for the total phase inductance of the salient pole electric machines shows that this parameter is constant with rotor position, and doesn´t vary as is assumed in many literatures. Using the correct expression for the total phase inductance, the current flux-linkage of the salient pole electric machines can be presented as function of phase inductance L(delta) and the angle gamma. In this paper these parameters are further investigated The influence of the saliency effect and the load angle on these machine parameters is analysed. Also the relation between the total phase inductance and the dq-inductances is derived.
  • Keywords
    inductance; synchronous machines; angle gamma; current flux linkage; load angle; saliency effect; salient pole synchronous machines; total phase inductance; Circuits; Electric machines; Electric resistance; Electromagnetic induction; Electromagnetic modeling; Inductance; Mathematical model; Performance analysis; Stators; Synchronous machines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2007. ICEMS. International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    978-89-86510-07-2
  • Electronic_ISBN
    978-89-86510-07-2
  • Type

    conf

  • Filename
    4412178