Abstract :
A Portable environmental radiation monitoring system which is able to monitor both a scintillation detector and a high pressure ion chamber was developed. We applied Mourich´s spectrum-dose rate conversion(G(E) method) for measurement of dose rate and Beck´s energy band for natural radiation dose rate of Nal(Tl) Detector. Also man-made radiation dos rate against nuclear power plant such as Cs-137, Mn-54, C0- 58, Co-60, Ir-192 was measured.
Keywords :
dosimetry; ionisation chambers; radiation monitoring; solid scintillation detectors; Beck energy band; Co-58; Co-60; Cs-137; G(E) method; Ir-192; Mn-54; Mourich spectrum-dose rate conversion; NaI(Tl) detector; environmental radiation monitoring system; high pressure ion chamber; man-made radiation dose rate; natural radiation dose rate; nuclear power plant; scintillation detector; Connectors; Detectors; Energy measurement; Power generation; Pressure measurement; Radiation monitoring; Scintillation counters; Spectroscopy; System testing; Universal Serial Bus;