DocumentCode
469696
Title
Image quality evaluation of motion-contaminated calcified plaques in cardiac CT
Author
King, Martin ; Giger, Maryellen ; Suzuki, Kenji ; Pan, Xiaochuan
Author_Institution
Univ. of Chicago, Chicago
Volume
4
fYear
2007
fDate
Oct. 26 2007-Nov. 3 2007
Firstpage
2717
Lastpage
2720
Abstract
An automated method for evaluating the image quality of motion-contaminated calcified plaques in non contrast-enhanced cardiac CT was developed. This method consisted of using the rapid phase-correlated ROI (RP-ROI) reconstruction algorithm for generating a 4D series of calcified plaque images, and then extracting phase-correlated dynamic, morphological, and intensity-based features of the plaques. Velocity-based linear regression (VLR), multiple linear regression (MLR), and artificial neural network (ANN) regression models were used to predict plaque motion indices based on these extracted features. Since motion indices were reflective of the amount of motion that plaques underwent at multiple phases throughout the cardiac cycle, these indices represented metrics of image quality with respect to motion artifacts. Motion indices were predicted for sixty calcified plaques placed along the left and right coronary arterial trees in the dynamic NCAT phantom. In a five-fold cross-validation scheme involving independent testing groups of twelve plaques, average repeated measures concordance correlation coefficients for the VLR, MLR, and ANN models were 0.848 plusmn 0.022, 0.885 plusmn 0.014, and 0.950 plusmn 0.009. The motion indices predicted by the ANN regression model also were used to obtain optimal phases for image interpretation of individual plaques.
Keywords
blood vessels; cardiovascular system; computerised tomography; feature extraction; image reconstruction; medical image processing; neural nets; phantoms; regression analysis; ANN regression model; artificial neural network regression models; cardiac CT; concordance correlation coefficients; coronary arterial trees; dynamic NCAT phantom; feature extraction; image interpretation; image quality; image quality evaluation; motion-contaminated calcified plaques; multiple linear regression; phase-correlated ROI reconstruction algorithm; plaque motion indices; velocity-based linear regression; Arteries; Artificial neural networks; Computed tomography; Heart rate; Image quality; Image reconstruction; Imaging phantoms; Lesions; Linear regression; Predictive models; Cardiac CT; ROI reconstruction; coronary calcium; image quality;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location
Honolulu, HI
ISSN
1095-7863
Print_ISBN
978-1-4244-0922-8
Electronic_ISBN
1095-7863
Type
conf
DOI
10.1109/NSSMIC.2007.4436705
Filename
4436705
Link To Document