Title :
Development of a position-sensitive detector for TOF-PET
Author :
Moriya, T. ; Omura, T. ; Watanabe, M. ; Yamashita, T.
Author_Institution :
Central Res. Lab., Hamamatsu
fDate :
Oct. 26 2007-Nov. 3 2007
Abstract :
A position-sensitive detector (PS-detector) for a time-of-flight (TOF) PET system has been developed and evaluated. The PS-detector consists of a flat panel position- sensitive photomultiplier tube (PS-PMT; Hamamatsu R8400-00- M64 MOD) and 2.9 mm times 2.9 mm times 20 mm LYSO crystals arranged in a 16 times 16 array. The PS-PMT has eight stages of metal channel dynode and 8times8 multiple anodes in a 52.0 mm square times 14.8 mm high metal can package. In order to compensate for the non-uniform amplitude from the multiple anodes of the PS-PMT, an application specific integrated circuit (ASIC) having 64-channel variable gain amplifiers is attached to the front-end circuits. The ASIC also has a readout circuit to reduce 64-channel outputs down to four position signals and an energy signal. The performance of PS-detector was evaluated for TOF-PET application. The coincidence response functions (CRFs) were measured by scanning a 22Na point source with 0.4 mm steps across the center of a pair of the PS-detectors. The average FWHM value of the CRFs is 2.3 mm. The energy resolution corresponding to each crystal element at 511 keV is 10.9% on the average. The timing resolutions of the PS-detector at FWHM, with a BaF2 reference detector, range from 421 ps to 787 ps, with an average of 505 ps. A new PS-PMT having high QE is now under development. The timing resolutions of the new PS-PMT coupled to a LaBr3 and a LYSO single crystal are 236 ps FWHM and 366 ps FWHM, respectively, with a BaF2 reference detector. We are developing a new TOF-PET system with PS-detectors.
Keywords :
application specific integrated circuits; nuclear electronics; photomultipliers; position sensitive particle detectors; positron emission tomography; solid scintillation detectors; ASIC; BaF2 reference detector; LYSO crystal; PS-PMT; TOF-PET; application specific integrated circuit; coincidence response function; electron volt energy 511 keV; flat panel photomultiplier tube; front-end circuit; metal channel dynode; position-sensitive detector; size 2.9 mm; size 20 mm; time 236 ps; time 366 ps; time 421 ps to 787 ps; variable gain amplifier; Anodes; Application specific integrated circuits; Crystals; Energy resolution; Gain; Integrated circuit packaging; Photomultipliers; Position sensitive particle detectors; Positron emission tomography; Timing;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
DOI :
10.1109/NSSMIC.2007.4436728