• DocumentCode
    469738
  • Title

    Three-dimensional image reconstruction for CCD camera based optical computed tomography scanner

  • Author

    Thomas, Hubertus M. ; Devakumar, D. ; Ravindran, Paul B.

  • Author_Institution
    Christian Med. Coll. Hosp., Vellore
  • Volume
    4
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    2965
  • Lastpage
    2967
  • Abstract
    Gel dosimetry is the best tool for three dimensional evaluation of radiation dose. Radiation dose can be measured from the reconstructed images of the gel. The aim of this study was to develop three-dimensional image reconstruction software for a CCD camera based cone beam optical computed tomography (OCT) scanner. In this study FDK reconstruction algorithm was implemented using C language and the quality of the reconstructed images were observed. The projections were acquired using an in-house prototype OCT scanner. The scanner design includes a broad beam light source, a scanning water tank, a turn table, a polyethylene terraphthalate container and a scientific camera for imaging. Multiple projection images were obtained along a circular trajectory for every degree from 1 degree to 180 degree. The objects imaged were a 4 mm diameter opaque rod placed at the centre of the axis of rotation and a 5 mm diameter glass capillary tube with a bore of 1 mm diameter placed 2.4 cm off centre. The reconstruction of 240 slices of each object was completed in 32 minutes. The diameter of central bore of the capillary tube that was measured from reconstructed image was about 0.9 mm giving an error of only 0.1 mm. Refraction and reflection of light at the walls of the container led to some artifacts. The preprocessing of input dataset enabled noise suppression The CNR values of the preprocessed images showed significantly higher values than their non processed counterparts. This study has enabled implementation of three- dimensional image reconstruction software for a CCD camera based cone beam optical computed tomography scanner.
  • Keywords
    biomedical optical imaging; computerised tomography; dosimetry; image reconstruction; medical image processing; noise; CCD camera; FDK reconstruction algorithm; broad beam light source; dosimetry; light reflection; light refraction; noise suppression; optical computed tomography scanner; polyethylene terraphthalate container; scanning water tank; three-dimensional image reconstruction; Boring; Charge coupled devices; Charge-coupled image sensors; Computed tomography; Containers; Data preprocessing; Image reconstruction; Optical beams; Optical computing; Optical refraction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436756
  • Filename
    4436756