• DocumentCode
    469772
  • Title

    Hybrid Monte Carlo simulation in Positron Emission Tomography

  • Author

    Sarrhini, Otman ; Bentourkia, M. Hamed

  • Author_Institution
    Univ. de Sherbrooke, Sherbrooke
  • Volume
    4
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    3191
  • Lastpage
    3196
  • Abstract
    Positron Emission Tomography (PET) offers the possibility to measure quantitatively the radiotracer distribution in tissues of interest. However, a number of physical issues must be accurately addressed in order to fully achieve this potential. The scattered radiation is one of the most challenging tasks among these issues. Up to now, Monte Carlo simulation (MC) is the ideal technique to evaluate and correct for the scattered photons. Nevertheless, these simulations are often complex and CPU time consuming. In this work, we have developed a combined MC simulations and analytical calculations for the small animal PET imaging systems. As a first step, MC simulation was performed only for the photon interactions within the studied object. The detection efficiency was analytically calculated as the energy deposited by the photons in the crystals and their attenuation in the surrounded crystal packages. The inter-crystal scatter was modeled by convolving the simulated data with the detector scatter kernels that were experimentally assessed from the line source measurements. The results showed good agreements between the measured and the simulated images. This technique, which allowed to substantially reduce the execution time without losing accuracy, can be easily implemented for the scatter and attenuation correction in PET imaging.
  • Keywords
    Monte Carlo methods; expectation-maximisation algorithm; image reconstruction; medical image processing; positron emission tomography; radioactive tracers; detection efficiency; detection probability matrix calculation; hybrid Monte Carlo simulation; image reconstruction; maximum likelihood expectation maximization algorithm; photon interactions; positron emission tomography; radiotracer distribution; sinograms; small animal PET imaging systems; Analytical models; Animals; Attenuation; Detectors; Electromagnetic scattering; Image analysis; Packaging; Particle scattering; Photonic crystals; Positron emission tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436804
  • Filename
    4436804