DocumentCode :
469815
Title :
An evaluation of iterative reconstruction strategies on mediastinal lesion detection using hybrid Ga-67 SPECT images
Author :
Pereira, N.F. ; Gifford, H.C. ; Pretorius, P.H. ; Farncombe, T. ; Smyczynski, M. ; Licho, R. ; Schneider, P. ; King, M.A.
Author_Institution :
Univ. of Massachusetts, Amherst
Volume :
5
fYear :
2007
fDate :
Oct. 26 2007-Nov. 3 2007
Firstpage :
3486
Lastpage :
3490
Abstract :
Hybrid LROC studies can be used to more realistically assess the impact of reconstruction strategies, compared to those constructed with digital phantoms. This is because hybrid data provides the background variability that is present in clinical imaging, as well as, control over critical imaging parameters, required to conduct meaningful tests. Hybrid data is obtained by adding Monte Carlo simulated lesions to disease free clinical projection data. Due to Ga-67 being a particularly challenging radionuclide for imaging, we use Ga- 67 hybrid SPECT data to study the effectiveness of the various correction strategies developed to account for degradations in SPECT imaging. Our data was obtained using GE-VG dual detector SPECT-CT camera. After determining a target lesion contrast we conduct pilot LROC studies to obtain a near-optimal set of reconstruction parameters for the different strategies individually. These near-optimal parameters are then used to reconstruct the final evaluation study sets. All LROC study results reported here were obtained employing human observers only. We use final LROC study results to assess the impact of attenuation compensation, scatter compensation and detector resolution compensation on data reconstructed with the RBI-EM algorithm. We also compare these with FBP reconstructions of the same dataset. Our experiment indicates an improvement in detection accuracy, as various degradations inherent in the image acquisition process are compensated for in the reconstruction process.
Keywords :
Monte Carlo methods; biological organs; expectation-maximisation algorithm; image reconstruction; medical image processing; sensitivity analysis; single photon emission computed tomography; GE-VG dual detector; Monte Carlo simulated lesions; RBI-EM algorithm; SPECT-CT camera; attenuation compensation; detector resolution compensation; hybrid Ga-67 SPECT images; hybrid LROC studies; image acquisition process; iterative reconstruction strategies; localization ROC; mediastinal lesion detection; scatter compensation; Cameras; Degradation; Detectors; Diseases; Humans; Image reconstruction; Imaging phantoms; Lesions; Monte Carlo methods; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
Conference_Location :
Honolulu, HI
ISSN :
1095-7863
Print_ISBN :
978-1-4244-0922-8
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2007.4436881
Filename :
4436881
Link To Document :
بازگشت