DocumentCode
469950
Title
Damage annealing in irradiated Geiger detectors
Author
Vasile, Stefan
Author_Institution
aPeak Inc., Newton
Volume
2
fYear
2007
fDate
Oct. 26 2007-Nov. 3 2007
Firstpage
1322
Lastpage
1324
Abstract
We evaluate room temperature and accelerated defect annealing of Geiger detectors irradiated with 55 MeV protons. Parameters governing the annealing rate are extracted. We find that damage annealing occurs faster at higher fluence and attribute it to defect interaction. Moderate temperature annealing is capable of effectively removing up to 85% of the radiation damage.
Keywords
Geiger counters; annealing; position sensitive particle detectors; proton effects; radiation effects; Geiger detector; accelerated defect annealing; electron volt energy 55 MeV; pixel detector arrays; proton irradiation; radiation damage; temperature 293 K to 298 K; Acceleration; Annealing; Probability; Protons; Radiation detectors; Sensor arrays; Silicon; Temperature; Testing; Vehicle detection;