• DocumentCode
    469976
  • Title

    Study of the spectral response of CZT multiple-electrode detectors

  • Author

    Abbene, L. ; Sordo, S. Del ; Fauci, F. ; Gerardi, G. ; La Manna, A. ; Raso, G. ; Cola, A. ; Perillo, E. ; Raulo, A. ; Gostilo, V. ; Stumbo, S.

  • Author_Institution
    Univ. di Palermo, Palermo
  • Volume
    2
  • fYear
    2007
  • fDate
    Oct. 26 2007-Nov. 3 2007
  • Firstpage
    1525
  • Lastpage
    1530
  • Abstract
    Cadmium zinc telluride (CZT) is a promising material for room temperature X-ray and gamma-ray detectors. The high atomic number and the wide band-gap give high quantum efficiency and good room temperature performances. Due to hole trapping, particular electrode structures have been developed to provide single-charge carrier collection (electrons), exploiting the excellent charge transport properties of the electrons. In this work, the spectroscopic performances of two CZT detectors (CZT1: 5 mm times 5 mm times 0.90 mm; CZT2: 4.8 mm times 5 mm times 0.55 mm) with five electrodes (cathode, anode and three steering electrodes) were studied. The anode-collecting electrode, surrounded by three steering electrodes (biased for optimum charge collection), is mostly sensitive to electron carriers, overcoming the effects of hole trapping in the measured spectra (hole tailing). We investigated on the spectroscopic response (241Am source; 59.5 keV) of the detectors at different bias voltages of the electrodes. The detectors exhibit excellent energy resolution (CZT1: 2.0% FWHM at 59.5 keV; CZT2: 1.7% FWHM at 59.5 keV; working temperature -10degC) and low tailing (CZT1: FW.1M to FWHM ratio of 1.93 at 59.5 keV; CZT2: 2.35 at 59.5 keV). This study stresses on the excellent spectroscopic properties of the CZT detectors equipped with a custom anode layout, making them very attractive candidates as x-ray spectrometers mainly for medical applications.
  • Keywords
    X-ray detection; X-ray spectrometers; electron traps; gamma-ray detection; hole traps; semiconductor counters; CZT multiple-electrode detectors; X-ray detector; X-ray spectrometers; cadmium zinc telluride; charge transport properties; electron carriers; energy resolution; gamma-ray detectors; hole trapping; room temperature; single-charge carrier collection; spectroscopic properties; temperature 293 K to 298 K; wide band-gap; Anodes; Cadmium compounds; Charge carrier processes; Electrodes; Electron traps; Gamma ray detectors; Photonic band gap; Spectroscopy; Temperature; Zinc compounds; CZT detectors; multiple electrode detectors; small pixel effect; steering electrodes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • Conference_Location
    Honolulu, HI
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4437289
  • Filename
    4437289