Abstract :
In order to cope with the onset of adverse LHC beam conditions, particularly hadronic showers caused by a misaligned beam, the experiment is meant to be equipped with a beam-conditions monitor (BCM). The system will be based on chemical-vapor deposition (CVD) diamonds, which have been proven to withstand radiation doses as they may occur in LHC accident scenarios. Its design and implementation is described here.
Keywords :
chemical vapour deposition; particle beam diagnostics; BCM; CERN; LHCb; beam-conditions monitor; chemical-vapor deposition diamonds; hadronic showers; Collision mitigation; Condition monitoring; Dark current; Diode lasers; Large Hadron Collider; Magnetic sensors; Metallization; Particle beams; Sensor systems; System testing;