DocumentCode :
471424
Title :
Combination 3D TOP with 2D PC MRA Techique for Cerebral Blood Flow Volume Measurement
Author :
Guo, G. ; Wu, RH ; Zhang, YP ; Guan, JT ; Guo, YL ; Cheng, Y. ; terBrugge, K. ; Mikulis, D.J.
Author_Institution :
Med. Imaging & Central Lab., Shantou Univ. Med. Coll.
fYear :
2006
fDate :
Aug. 30 2006-Sept. 3 2006
Firstpage :
489
Lastpage :
492
Abstract :
To demonstrate the discrepancy of cerebral blood flow volume (BFV) estimation with 2D phase-contrast (2D PC) MRA guided with 3D time-of-flight (3D TOF) MR localization by using an "internal" standard. 20 groups of the common (CCA), internal (ICA), and external (ECA) carotid arteries in 10 healthy subjects were examined with 2D PC MRA guided by 3D TOF MR angiograms. The sum BFV of the internal and external carotid arteries was then compared with the ipsilateral common carotid artery flow. An accurate technique would demonstrate no difference. The difference was therefore a measure of accuracy of the method. 3D TOF MRA localization is presented to allow the determination of a slice orientation to improve the accuracy of 2D PC MRA in estimate the BFV. By using the combined protocols, there was better correlation in BFV estimate between the sum of ICA+ECA with the ipsilateral CCA (R=0.729, P=0.000). The inconsistency (meanplusmnSD) was found to be 6.95plusmn 5.95% for estimate the BFV in ICA+ECA and ipsilateral CCA. The main inconsistency was contributed to the ECA and its branches. Guided with 3D TOF MRA localization, 2D PC MRA is more accurate in the determination of blood flow volume in the carotid arteries
Keywords :
biomedical MRI; blood flow measurement; blood vessels; brain; neurophysiology; 2D phase-contrast image; 3D TOF MR angiograms; 3D time-of-flight MR localization; cerebral blood flow volume measurement; external carotid arteries; internal carotid arteries; ipsilateral common carotid artery flow; magnetic resonance angiogram techique; Bifurcation; Biomedical imaging; Blood flow; Carotid arteries; Coils; Hospitals; Independent component analysis; Magnetic resonance imaging; Protocols; Volume measurement; Cerebral Blood Flow; Magnetic Resonance Imaging; Phase Contrast; Quantification; Three-Dimensional Localization;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
Conference_Location :
New York, NY
ISSN :
1557-170X
Print_ISBN :
1-4244-0032-5
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2006.259362
Filename :
4461793
Link To Document :
بازگشت