• DocumentCode
    471804
  • Title

    An Optimal Spot-electrodes Array for Electrical Impedance Cardiography Through Determination of Impedance Mapping of a Regional Area along the Medial Line on the Thorax

  • Author

    Ikarashi, Akira ; Nogawa, Masamichi ; Yamakoshi, Takehiro ; Tanaka, Shinobu ; Yamakoshi, Ken-ichi

  • Author_Institution
    Div. of Innovative Technol. & Sci., Kanazawa Univ.
  • fYear
    2006
  • fDate
    Aug. 30 2006-Sept. 3 2006
  • Firstpage
    3202
  • Lastpage
    3205
  • Abstract
    Electrical impedance or admittance cardiography is a simple method for non-invasive, continuous measurement the stroke volume and cardiac output. For the electrical impedance cardiography, the band-electrodes array proposed by Kubicek et al has been widely used, and various spot-electrodes array have been experimented in search of a less uncomfortable and equally reliable electrodes array that is easier to attach. From the uniformity of current distribution on the thorax, we have reinvestigated focusing on the measurement of contour maps of static and pulsatile components of a regional area along the medial line on the frontal part of the thorax. Consequently, the appropriate electrodes locations for current injection were determined as the back of an ear and on the lower abdomen, while those for voltage pick-up was on the medial portion at the level of clavicle and on the portion above the xiphisternum. Preliminary comparison experiments between the cardiac output values obtained by the electrical impedance cardiography and by a pulse dye-densitometry showed a fairy good agreement
  • Keywords
    biomedical electrodes; biomedical measurement; electric impedance; electrocardiography; volume measurement; band-electrodes array; cardiac output; electrical admittance cardiography; electrical impedance cardiography; impedance mapping; noninvasive measurement; optimal spot-electrodes array; pulsatile components; pulse dye-densitometry; static components; stroke volume measurement; thorax; voltage pick-up; Admittance measurement; Area measurement; Cardiography; Current distribution; Current measurement; Electric variables measurement; Electrodes; Impedance measurement; Thorax; Volume measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1557-170X
  • Print_ISBN
    1-4244-0032-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2006.260748
  • Filename
    4462478