• DocumentCode
    471903
  • Title

    Guidelines for Plunge Needle Recording for Effective Detection of Purkinje Activation

  • Author

    Dosdall, Derek J. ; Huang, Jian ; Smith, William M. ; Allison, J. Scott ; Allred, James D. ; Ideker, Raymond E.

  • Author_Institution
    Dept. of Biomed. Eng., Alabama Univ., Birmingham, AL
  • fYear
    2006
  • fDate
    Aug. 30 2006-Sept. 3 2006
  • Firstpage
    3915
  • Lastpage
    3918
  • Abstract
    Direct recording of Purkinje fiber activity may lead to a better understanding of the role of the specialized conduction system in pathological cardiac conditions. Two studies were conducted in pigs to determine guidelines for effective plunge needle recording techniques. In the first experiment, Purkinje fiber activations were recorded at 16 KHz with 3 bipolar electrodes (2 mm spacing) on epoxy plunge needles, and were later lowpass filtered and downsampled to determine the rate required for effective identification of Purkinje activation. Purkinje spikes were identifiable at sampling rates of 4 KHz and greater, but were not easily distinguished at sampling rates of 2 KHz or less. In the second experiment, 4 plunge needles with 15 electrodes (1 mm spacing) were inserted 8 times into different locations around the left ventricle. Unipolar (15 per needle) and bipolar (14 per needle) signals were recorded simultaneously at a sampling rate of 8 KHz. Purkinje activations were identified in 13/32 plunge needle sites. Of the 13 sites with identified Purkinje activations, 10 were within 2 mm of the endocardium. Bipolar recordings demonstrated Purkinje potentials that were 13% of the amplitude of the following myocardial activation, while unipolar recordings from the same electrodes recorded Purkinje potentials that were only 5% of the amplitude of the following myocardial activations. Three guidelines were developed for effective Purkinje fiber recording: 1) use a minimum sampling rate of 4 KHz., 2) record near the endocardium, and 3) use bipolar rather than unipolar recording electrodes
  • Keywords
    bioelectric potentials; biomedical electrodes; electrocardiography; needles; neurophysiology; 16 KHz; Purkinje fiber activity recording; Purkinje potential; bipolar electrodes; epoxy plunge needles; left ventricle; myocardial activation; pathological cardiac condition; plunge needle recording technique; specialized conduction system; unipolar recording electrode; Biomedical engineering; Cities and towns; Defibrillation; Electrodes; Guidelines; Hemodynamics; Myocardium; Needles; Sampling methods; USA Councils; Purkinje fiber activation; cardiac arrhythmias; electrophysiology; plunge needle recording;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1557-170X
  • Print_ISBN
    1-4244-0032-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2006.259488
  • Filename