DocumentCode :
47412
Title :
Current Ratio Transfer Standard and Improved Equivalent Ampere Turn Method
Author :
Takahashi, Koichi ; Yamawaki, Minoru ; Tadokoro, T.
Author_Institution :
Japan Electr. Meters Inspection Corp., Tokyo, Japan
Volume :
62
Issue :
6
fYear :
2013
fDate :
Jun-13
Firstpage :
1716
Lastpage :
1722
Abstract :
This paper describes a method to calibrate high current (20 kA) transformers, using a current comparator with a maximum test current of 100 A as a primary standard. In order to fill the large gap in the test current between 20 kA and 100 A, two novel techniques are developed, i.e., 1) the current-ratio transfer standard (CRTS), and 2) the improved equivalent ampere-turn method. The CRTS is a two-stage current transformer with two selectable current ratios of 500A/5A and 100A/5A. The two ratios are realized by the selection of parallel or series combination in the primary windings of the CRTS. The design and the performance of the 100-A primary standard, a coaxial-type self-calibratable current comparator, is also described.
Keywords :
calibration; current transformers; electric current measurement; transformer windings; CRTS; coaxial-type self-calibratable current comparator; current 100 A; current 20 kA; current 5 A; current 500 A; current ratio transfer standard; improved equivalent ampere turn method; improved equivalent ampere-turn method; primary windings; two-stage current transformer calibration; Current comparators; current measurement; current transformers; measurement standards; power distribution electromagnetic interface; power measurement;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2013.2256711
Filename :
6513253
Link To Document :
بازگشت