DocumentCode :
474927
Title :
Condition monitoring of pantograph contact strip
Author :
Ostlund, Stefan ; Gustafsson, A. ; Buhrkall, L. ; Skoglund, Mikael
Author_Institution :
Kungliga Tek. Hogskolan, Stockholm
fYear :
2008
fDate :
18-20 June 2008
Firstpage :
1
Lastpage :
6
Abstract :
A common issue in electric railway operation is the wear of the pantograph contact strip. This is especially pronounced with ice or rime frost on the overhead line that causes arcing between the contact strip and the contact wire. To monitor the contact strip it is possible to utilise the fact that arcing between the contact strip and the overhead line generates a DC component in the AC locomotive current. The paper presents a method for condition based maintenance of the contact strip. The wear of the contact strip is predicted by monitoring the running distance of the pantograph as well as the DC component of the locomotive current. To evaluate the method, measurements have been carried out on a Swedish Re locomotive during winter conditions.
Keywords :
condition monitoring; electric locomotives; mechanical contact; pantographs; power overhead lines; railway electrification; wires (electric); AC locomotive current; DC component; Swedish Re locomotive; condition monitoring; contact wire; electric railway operation; overhead line; pantograph contact strip; winter condition; DC current; arcing; condition monitoring; contact strip;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Railway Condition Monitoring, 2008 4th IET International Conference on
Conference_Location :
Derby
ISSN :
0537-9989
Print_ISBN :
978-0-86341-927-0
Type :
conf
Filename :
4580867
Link To Document :
بازگشت