• DocumentCode
    477332
  • Title

    Generation and dose distribution measurement of flash x-ray in KALI-5000 system

  • Author

    Mondal, J. ; Menon, R. ; Roy, Amitava ; Mitra, S. ; Kumar, D.D.P. ; Sharma, Archana ; Mittal, K.C. ; Nagesh, K.V. ; Chakravarthy, D.P.

  • Author_Institution
    Accelerator and Pulse Power Division, Bhabha Atomic Research Center, Mumbai, India
  • Volume
    1
  • fYear
    2007
  • fDate
    17-22 June 2007
  • Firstpage
    843
  • Lastpage
    845
  • Abstract
    The high intensity pulsed electron beam of KALI-5000 system is used to develop a flash x-ray source. The KALI-5000 system is capable of generating intense relativistic electron beam (IREB) of 1 MeV, 60 kA and 100 ns when connected to impedance matched electron beam diode. This system is operated in 6 GW, 100 ns duration to produce the bremsstrahlung flash x-ray on a tantalum target of planner anode-cathode geometry. The axial and the radial dose distribution are characterized using CaSO4: Dy TLDs (thermoluminescent dosimeter) as well as using the optical densitometer to measure the dose distribution of the exposed x-ray film. The measured dose distribution by TLDs and the optical densitometer plus x-ray film matches within ± 5%.
  • Keywords
    Atomic beams; Atomic measurements; Calibration; Diodes; Electron beams; Electron optics; Impedance; Optical films; Radiography; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2007 16th IEEE International
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-0913-6
  • Electronic_ISBN
    978-1-4244-0914-3
  • Type

    conf

  • DOI
    10.1109/PPPS.2007.4651970
  • Filename
    4651970