    Design and Experimental Study on the Pulverized Coal Concentration Sensor Based on Gamma-Ray Absorption Method

  • Author

    Duan, Quansheng ; Liu, Jizhen ; Wu, Zhifang

  • Author_Institution
    Coll. of Control Sci. & Eng., North China Electr. Power Univ., Beijing
  • Volume
    1
  • fYear
    2008
  • fDate
    19-20 Dec. 2008
  • Firstpage
    901
  • Lastpage
    906
  • Abstract
    The device was developed to accurately measure the Concentration of pulverized coal in the pneumatic conveying pipe. The sensor assembly was composed of gamma-ray source, tube of the sensor, ionization chamber fill with inert gas electrometer and lead cannon tube shield. The gamma point source was fixed at the cross-section centre of the pipe, the collimation exit portal was vertical to the axis line of the conduct, in which the outgoing beam of the gamma rays was assumed at the plane 360 degrees; the profile of the ionization chamber was designed ring cross section, independent multi-cavity. The gamma-ray from the source penetrated the gas-solid two phase flow and the single tube wall, arrived at the corresponding independent cavity. The inert gas filled in the cavity was ionized by the gamma-ray, the ions was collected by the high voltage plates, the ionic stream was converted into direct voltage by the electrometer in the cavity, as the output of the cavity. The concentration of the corresponding sector in the tube could be determined according to the law of gamma-ray mutual effect with the matter. The arithmetic mean of the output voltages from the electrometers in the cavities of the ionization chamber was taken as the measured value of volume concentration of the pulverized coal in the tube. The proving trial shows that the input-output character of the sensor assembly was the phase distribution; the measuring accuracy was superior 2%, the gamma-ray radioactivity requirement was reduced obviously as only single tube wall was required to be penetrated by gamma-ray.
  • Keywords
    chemical sensors; chemical variables measurement; coal; conveyors; flow sensors; gamma-ray absorption; ionisation chambers; pipes; pneumatic systems; pulverised fuels; two-phase flow; collimation exit portal; concentration measurement; gamma-ray absorption method; gamma-ray mutual effect; gamma-ray radioactivity; gas-solid two phase flow; inert gas electrometer; ionization chamber; lead cannon tube shield; pneumatic conveying pipe; pulverized coal concentration sensor; single tube wall; Arithmetic; Assembly; Collimators; Electromagnetic wave absorption; Gamma ray detectors; Gamma rays; Gas detectors; Ionization chambers; Portals; Voltage; ?-ray absorption method; Pulverized Coal Concentration;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computational Intelligence and Industrial Application, 2008. PACIIA '08. Pacific-Asia Workshop on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-0-7695-3490-9
  • Type

    conf

  • DOI
    10.1109/PACIIA.2008.78
  • Filename
    4756690