• DocumentCode
    481872
  • Title

    Energy storage and power management for typical 4Q-load

  • Author

    Baalbergen, J.F. ; Bauer, P.

  • Author_Institution
    Delft Univ. of Technol., Delft
  • fYear
    2008
  • fDate
    10-13 Nov. 2008
  • Firstpage
    2332
  • Lastpage
    2337
  • Abstract
    The efficiency of a diesel generator is dependent on the ratio determined by the average power divided by the peak power of the generator. The smaller this ratio, the lower the efficiency. Furthermore some loads can regenerate energy. In small grids this energy is mostly not needed elsewhere and should be dissipated. A solution solving both above mentioned problems is using an energy storage device in the system. This storage can be used for peak shaving and storing regenerated energy. This paper focuses on a generator-set with energy storage. Six different power management strategies are discussed Calculation of the costs shows that adding an energy storage device lowers the cost for all methods. Verification with simulation and experiments has been carried out.
  • Keywords
    diesel-electric generators; energy storage; load management; 4Q-load; diesel generator; energy storage device; power management strategies; Batteries; Capacitors; Costs; Energy management; Energy storage; Mesh generation; Power generation; Power supplies; Power system management; Technology management; Costs; Diesel driven generators; Energy conservation; Energy storage; Lithium ion battery; Power electronics; Super capacitor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, 2008. IECON 2008. 34th Annual Conference of IEEE
  • Conference_Location
    Orlando, FL
  • ISSN
    1553-572X
  • Print_ISBN
    978-1-4244-1767-4
  • Electronic_ISBN
    1553-572X
  • Type

    conf

  • DOI
    10.1109/IECON.2008.4758321
  • Filename
    4758321