• DocumentCode
    482242
  • Title

    Load characteristics of induction motor made of Soft Magnetic Composite (SMC)

  • Author

    Fukuda, Tomohiro ; Morimoto, Masayuki

  • Author_Institution
    Dept. of Electr. & Electron. Eng., Tokai Univ., Hiratsuka
  • fYear
    2008
  • fDate
    17-20 Oct. 2008
  • Firstpage
    53
  • Lastpage
    56
  • Abstract
    This paper presents experimental comparison of the load characteristics of soft magnetic composite (SMC) induction motor and conventional laminated induction motor. SMC is used for the stator core of induction motor. As the result, efficiency difference between SMC motor and conventional laminated motor is only 3.7% in spite of the permeability of SMC is 20% lower than conventional electromagnetic steel.
  • Keywords
    induction motors; magnetic cores; stators; SMC; induction motor load characteristics; soft magnetic composite; stator core; Equivalent circuits; Induction motors; Magnetic cores; Magnetic flux; Magnetic materials; Manufacturing; Sliding mode control; Soft magnetic materials; Stator cores; Steel;