Title :
Designing air cooling rotor for evaporative cooling turbo generator
Author :
Xiong, Bin ; Gu, Guobiao
Author_Institution :
Evaporative Cooling Lab., Chinese Acad. of Sci., Beijing
Abstract :
Turbo generator with evaporative cooling stator and air cooling rotor possesses many excellent qualities for mid unit. The stator bars and core are immerged in evaporative coolant, which could be cooled fully. The rotor bars are cooled by air inner cooling mode, and the cooling effect compared with hydrogen and water cooling mode is limited. So an effective ventilation system has to been employed to insure the reliability of rotor. This paper presents the comparisons of stator temperature distribution between evaporative cooling mode and air cooling mode, and the designing of rotor ventilation system combined with evaporative cooling stator.
Keywords :
power system reliability; turbogenerators; ventilation; air cooling rotor ndesign; air inner cooling mode; evaporative cooling stator; rotor reliability; stator bars; stator temperature distribution; turbo generator; ventilation system; Bars; Coolants; Cooling; Costs; Hydrogen; Power generation; Rotors; Stator cores; Turbogenerators; Ventilation; air cooling; axial-radial ventilation; evaporative cooling; turbo generator;
Conference_Titel :
Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-3826-6
Electronic_ISBN :
978-7-5062-9221-4