• DocumentCode
    482359
  • Title

    Designing air cooling rotor for evaporative cooling turbo generator

  • Author

    Xiong, Bin ; Gu, Guobiao

  • Author_Institution
    Evaporative Cooling Lab., Chinese Acad. of Sci., Beijing
  • fYear
    2008
  • fDate
    17-20 Oct. 2008
  • Firstpage
    557
  • Lastpage
    560
  • Abstract
    Turbo generator with evaporative cooling stator and air cooling rotor possesses many excellent qualities for mid unit. The stator bars and core are immerged in evaporative coolant, which could be cooled fully. The rotor bars are cooled by air inner cooling mode, and the cooling effect compared with hydrogen and water cooling mode is limited. So an effective ventilation system has to been employed to insure the reliability of rotor. This paper presents the comparisons of stator temperature distribution between evaporative cooling mode and air cooling mode, and the designing of rotor ventilation system combined with evaporative cooling stator.
  • Keywords
    power system reliability; turbogenerators; ventilation; air cooling rotor ndesign; air inner cooling mode; evaporative cooling stator; rotor reliability; stator bars; stator temperature distribution; turbo generator; ventilation system; Bars; Coolants; Cooling; Costs; Hydrogen; Power generation; Rotors; Stator cores; Turbogenerators; Ventilation; air cooling; axial-radial ventilation; evaporative cooling; turbo generator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-3826-6
  • Electronic_ISBN
    978-7-5062-9221-4
  • Type

    conf

  • Filename
    4770763