DocumentCode :
482365
Title :
Calculation of temperature distribution in the stator of larger evaporative cooling turbo-generator
Author :
Jian-hong, Guo ; De-ping, Fu ; De-shu, Hang ; Ximing, Li
Author_Institution :
Inst. Electr. Eng., Chinese Acad. of Sci., Beijing
fYear :
2008
fDate :
17-20 Oct. 2008
Firstpage :
579
Lastpage :
584
Abstract :
Evaporative cooling for generator stator is an independent innovative technology developed by China. The development of the technology is in research stage. The mechanism of applying phase transition for evaporative cooling of the generator stator was introduced. according to the 300 MW turbo-generator design specification, and based on the two phase fluxion of cooling medium in the hollow conductor, we proposed the calculation of the medium fluxion resistance and the evaporative point of the cooling medium in the hollow conductor. We also carried out analysis of the temperature distribution along the stator winding and compared our calculation with the experiment results to demonstrate the feasibility of the proposed calculation.
Keywords :
conductors (electric); stators; temperature distribution; turbogenerators; evaporative cooling; hollow conductor; phase transition; power 300 MW; stator winding; temperature distribution; turbogenerator design; two phase fluxion; Conductors; Copper; Hydraulic turbines; Hydrogen; Insulation; Liquid cooling; Prototypes; Stator windings; Temperature distribution; Wire; evaporative cooling; forced inner cooling; turbine-generator; two phase flow;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-3826-6
Electronic_ISBN :
978-7-5062-9221-4
Type :
conf
Filename :
4770769
Link To Document :
بازگشت