• DocumentCode
    482632
  • Title

    Comparative study on the current decoupled control for the three-phase voltage-source PWM rectifier in the synchronous reference frame

  • Author

    Chen, Yaojun ; Zhong, Yanping ; Chen, Dan ; Lai, Xiangdong

  • Author_Institution
    Dept. of Electron. Countermeasure, Air Force Radar Acad., Wuhan
  • fYear
    2008
  • fDate
    17-20 Oct. 2008
  • Firstpage
    1838
  • Lastpage
    1842
  • Abstract
    The current state feedback decoupled control strategy in the synchronous reference frame is generally used for the three-phase voltage-source PWM rectifier, which lies in the precise inductance measurement value. In this paper, the effect of the systempsilas performance with the varying of the inductance measurement error and the synchronous frequency is investigated, and the current error feed-forward decoupled control strategy is presented, comparative analysis indicates the fact that this strategy is not sensitive to the inductance and the synchronous frequency. Finally, results of the system simulation and experiment by using the mentioned strategy are presented.
  • Keywords
    PWM rectifiers; electric current control; feedback; current error feedforward decoupled control strategy; current state feedback decoupled control strategy; inductance measurement value; synchronous frequency; synchronous reference frame; three-phase voltage-source PWM rectifier; Control systems; Error correction; Feedforward systems; Frequency; Inductance measurement; Performance analysis; Pulse width modulation; Rectifiers; State feedback; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-3826-6
  • Electronic_ISBN
    978-7-5062-9221-4
  • Type

    conf

  • Filename
    4771036