DocumentCode :
482670
Title :
A Real-time digital simulation and testing system for SVC used in EAF power supply system
Author :
Shi, Xinchun ; Fu, Chao ; Ma, Weiwei ; Zhou, Guoliang
Author_Institution :
Key Lab. of Power Syst. Protection, North China Electr. Power Univ., Baoding
fYear :
2008
fDate :
17-20 Oct. 2008
Firstpage :
2017
Lastpage :
2021
Abstract :
This paper introduced a real-time digital modeling approach for electrical arc furnace (EAF) based on recorded field data. The model equaled the arc furnace to a current source controlled by the field data, and via adopting a phase locked technique, the synchronization between simulation and field data was performed, which made a long time real-time simulation possible. Besides, the model was used for evaluating the performance of SVC system which contributes to compensate Var and mitigate the harmonic and flicker caused by EAF. The simulation was implemented on the Real Time Digital Simulators (RTDS) and the results of simulation illustrate that the proposed EAF model and evaluation system can be used for testing a physical control system of SVC system and evaluating the control strategy.
Keywords :
arc furnaces; power supplies to apparatus; static VAr compensators; electrical arc furnace; field data; phase locked technique; physical control system testing; power supply system; real-time digital simulation; recorded field data; static Var compensator; Digital simulation; Furnaces; Power supplies; Power system harmonics; Power system modeling; Power system protection; Power system simulation; Real time systems; Static VAr compensators; System testing; arc furnace; close loop test; model; real time digital simulation; recorded field data;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-3826-6
Electronic_ISBN :
978-7-5062-9221-4
Type :
conf
Filename :
4771074
Link To Document :
بازگشت