Abstract :
Reclosing on a rotating motor after a brief power-off can bring serious dangerous due to excessive current and torque transients, especially to permanent magnet motors of line start. To avoid such potential threats, time-stepping finite element method was used to study the transient processes under different reclosing conditions. Combined with the numerical and theoretical analysis, a practical criterion for favorable reclosing conditions is proposed, which is expected to prevent the permanent magnet motor from damages during reclosing.
Keywords :
finite element analysis; matrix algebra; permanent magnet motors; transient analysis; fast reclosing analysis; line start permanent magnet motor; time-stepping finite element method; torque transients; transient processes; Coupling circuits; Electromagnetic coupling; Finite element methods; Magnetic analysis; Magnetic fields; Nonlinear equations; Permanent magnet motors; Rotors; Torque; Voltage;