• DocumentCode
    482968
  • Title

    Starting performance analysis of three-phase capacitor motor for beam pumping unit

  • Author

    Xiong, Suming ; Yang, Bingzhong ; Ni, Guangzheng

  • Author_Institution
    Coll. of Electr. Eng., Zhejiang Univ., Hangzhou
  • fYear
    2008
  • fDate
    17-20 Oct. 2008
  • Firstpage
    3489
  • Lastpage
    3492
  • Abstract
    Starting toque is computed based on two-dimensional (2-D) FEM with a field-circuit coupled analysis. It is discussed that the starting performance of three-phase capacitor motor is better than that of conventional induction motor, in particular, for the operating condition with starting capacitor. The results of calculation are compared to tested values, and it is verified that this new type motor lead to good operating performance in the application of beam pumping unit.
  • Keywords
    capacitor motors; finite element analysis; machine windings; 2D FEM; beam pumping unit; field-circuit coupled analysis; three-phase capacitor motor; Capacitors; Induction motors; Iron; Laser excitation; Magnetic cores; Performance analysis; Permeability; Saturation magnetization; Stator cores; Stator windings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-3826-6
  • Electronic_ISBN
    978-7-5062-9221-4
  • Type

    conf

  • Filename
    4771372