DocumentCode :
483166
Title :
Study on surge current and over-voltage of electric locomotive transformer
Author :
Luo, Liquan ; Wang, Yi ; Shi, WeiDong
Author_Institution :
Sch. of Electr. Eng., Beijing Jiaotong Univ., Beijing
fYear :
2008
fDate :
17-20 Oct. 2008
Firstpage :
4403
Lastpage :
4406
Abstract :
Loaded switches are frequent for the running electric locomotive. The frequencies, phases and amplitudes between the system voltage and residual voltage may be different when the transformer is put into use. The transient responses at different time points are thus analyzed to determine the optimal time to switch on the locomotive transformer and prevent the damage to the system.
Keywords :
electric locomotives; overvoltage protection; power transformers; surge protection; transient response; electric locomotive transformer; loaded switches; overvoltage; surge current; transient response; Circuits; Equations; Frequency; Inductance; Laboratories; Power system transients; Substations; Surges; Switches; Transient analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2008. ICEMS 2008. International Conference on
Conference_Location :
Wuhan
Print_ISBN :
978-1-4244-3826-6
Electronic_ISBN :
978-7-5062-9221-4
Type :
conf
Filename :
4771570
Link To Document :
بازگشت