DocumentCode
483358
Title
Delivering IEC 61000-4-2 current pulses through transmission lines at 100 and 330 ohm system impedances
Author
Grund, Evan ; Muhonen, Kathleen ; Peachey, Nathaniel
Author_Institution
Grund Tech. Solutions, LLC, San Jose, CA
fYear
2008
fDate
7-11 Sept. 2008
Firstpage
132
Lastpage
141
Abstract
Device testing using an IEC-compliant hand-held 150 pF/330 Omega discharge gun was compared to a 50 Omega IEC waveform pulser. Current waveforms were recorded and components tested with both pulsers. To understand effects of different pulse source impedances, the 50 Omega pulser was modified to operate at 100 and 330 Omega delivery impedances.
Keywords
electric impedance; transmission lines; IEC 61000-4-2 current pulses; current waveforms; device testing; discharge gun; pulse source impedances; resistance 100 ohm; resistance 330 ohm; system impedances; transmission lines; Electrostatic discharge; Fixtures; IEC standards; Impedance; Integrated circuit testing; Manufacturing; Pins; Stress; System testing; Transmission lines;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Overstress/Electrostatic Discharge Symposium, 2008. EOS/ESD 2008. 30th
Conference_Location
Tucson, AZ
Print_ISBN
978-1-58537-146-4
Electronic_ISBN
978-1-58537-147-1
Type
conf
Filename
4772125
Link To Document