• DocumentCode
    483358
  • Title

    Delivering IEC 61000-4-2 current pulses through transmission lines at 100 and 330 ohm system impedances

  • Author

    Grund, Evan ; Muhonen, Kathleen ; Peachey, Nathaniel

  • Author_Institution
    Grund Tech. Solutions, LLC, San Jose, CA
  • fYear
    2008
  • fDate
    7-11 Sept. 2008
  • Firstpage
    132
  • Lastpage
    141
  • Abstract
    Device testing using an IEC-compliant hand-held 150 pF/330 Omega discharge gun was compared to a 50 Omega IEC waveform pulser. Current waveforms were recorded and components tested with both pulsers. To understand effects of different pulse source impedances, the 50 Omega pulser was modified to operate at 100 and 330 Omega delivery impedances.
  • Keywords
    electric impedance; transmission lines; IEC 61000-4-2 current pulses; current waveforms; device testing; discharge gun; pulse source impedances; resistance 100 ohm; resistance 330 ohm; system impedances; transmission lines; Electrostatic discharge; Fixtures; IEC standards; Impedance; Integrated circuit testing; Manufacturing; Pins; Stress; System testing; Transmission lines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium, 2008. EOS/ESD 2008. 30th
  • Conference_Location
    Tucson, AZ
  • Print_ISBN
    978-1-58537-146-4
  • Electronic_ISBN
    978-1-58537-147-1
  • Type

    conf

  • Filename
    4772125