DocumentCode :
483358
Title :
Delivering IEC 61000-4-2 current pulses through transmission lines at 100 and 330 ohm system impedances
Author :
Grund, Evan ; Muhonen, Kathleen ; Peachey, Nathaniel
Author_Institution :
Grund Tech. Solutions, LLC, San Jose, CA
fYear :
2008
fDate :
7-11 Sept. 2008
Firstpage :
132
Lastpage :
141
Abstract :
Device testing using an IEC-compliant hand-held 150 pF/330 Omega discharge gun was compared to a 50 Omega IEC waveform pulser. Current waveforms were recorded and components tested with both pulsers. To understand effects of different pulse source impedances, the 50 Omega pulser was modified to operate at 100 and 330 Omega delivery impedances.
Keywords :
electric impedance; transmission lines; IEC 61000-4-2 current pulses; current waveforms; device testing; discharge gun; pulse source impedances; resistance 100 ohm; resistance 330 ohm; system impedances; transmission lines; Electrostatic discharge; Fixtures; IEC standards; Impedance; Integrated circuit testing; Manufacturing; Pins; Stress; System testing; Transmission lines;
fLanguage :
English