• DocumentCode
    490461
  • Title

    Design and Evaluation of Model-Based Compensators for the Control of Steam Generator Level

  • Author

    Kim, Keung Koo ; Meyer, John E. ; Lanning, David D. ; Bernard, John A.

  • Author_Institution
    Department of Nuclear Engineering, Massachusetts Institute of Technology 138 Albany Street, Cambridge, MA 02139
  • fYear
    1993
  • fDate
    2-4 June 1993
  • Firstpage
    2055
  • Lastpage
    2060
  • Abstract
    The design and evaluation of a controller that uses modelbased compensators to offset the inverse response behavior of water level in the steam generators of nuclear power plants is described. Included is a review of steam generator level dynamics, the development of a model that replicates the effects of feedwater and steam flowrate as well as temperature on steam generator level, the design of both the compensators and the overall controller, and the results of simulation studies in which the performance of this modelbased controller and existing analog ones were compared. The compensator-based controller is stable and its use significantly improves the controllability of steam generator level.
  • Keywords
    Coolants; Cost accounting; Force control; Human factors; Inductors; Influenza; Nuclear power generation; Power generation; Tellurium; Temperature control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    American Control Conference, 1993
  • Conference_Location
    San Francisco, CA, USA
  • Print_ISBN
    0-7803-0860-3
  • Type

    conf

  • Filename
    4793242