• DocumentCode
    490896
  • Title

    Experience with Hybrid Power Systems using Closed Cycle Vapor Turbogenerators

  • Author

    Gropper, J. ; Christopher, N.

  • Author_Institution
    Ormat Systems Inc., 500 Dermody Way, Sparks, Nevada 89431, United States of America
  • fYear
    1985
  • fDate
    14-17 Oct. 1985
  • Firstpage
    589
  • Lastpage
    594
  • Abstract
    During the past six or seven years, telecommunications companies, P & T administrations and manufacturers of power supply equipment have shown great interest in the development of hybrid power systems which combine converters using renewable sources or random characteristics (wind and solar) with fuel operated generators. Among these hybrid systems, applications where Closed Cycle Vapor Turbogenerator is the back-up power source have been used widely where enhanced reliability is desired. This paper presents the experience accumulated over the past several years with this category of hybrid system.
  • Keywords
    Character generation; Fuels; Hybrid power systems; Manufacturing; Power generation; Power supplies; Power system reliability; Solar power generation; Turbogenerators; Wind power generation; Automatic start-up; Hybrid system; Maintenance; Reliability; Turbogenerator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Telecommunications Energy Conference, 1985. INTELEC '85. Seventh International
  • Conference_Location
    Munich, Federal Republic of Germany
  • Print_ISBN
    3-8007-1429-9
  • Type

    conf

  • Filename
    4794290