• DocumentCode
    491557
  • Title

    Nuclear Effects on Communications Systems

  • Author

    Tolmie, Bernard R.

  • Author_Institution
    Joslyn Defense Systems, Inc./Shelburne, Vermont 05482
  • Volume
    2
  • fYear
    1986
  • fDate
    5-9 Oct. 1986
  • Abstract
    A portable EMP surge arrestor test set can assure the EMP protection level at the pin level on hardened systems. EMP protection devices are susceptible to degradation caused by lightning and man-made EMI transients. Devices such as Zeners, MOV´s, Gas Tubes and Filters are benign passive devices that protect electronic systems from EMP transients at the pin level. Degradation of these devices are normally not detectable by system operation. A portable EMP test set was developed that generates a transient on a protected pin and measures degradation of EMP protection devices before catastrophic failure.
  • Keywords
    Circuit testing; Clamps; Degradation; EMP radiation effects; Electromagnetic interference; Lightning; Protection; Qualifications; System testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Military Communications Conference - Communications-Computers: Teamed for the 90's, 1986. MILCOM 1986. IEEE
  • Type

    conf

  • DOI
    10.1109/MILCOM.1986.4805779
  • Filename
    4805779