• DocumentCode
    49390
  • Title

    Automatic Localization of the Anterior Commissure, Posterior Commissure, and Midsagittal Plane in MRI Scans using Regression Forests

  • Author

    Yuan Liu ; Dawant, Benoit M.

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., Vanderbilt Univ., Nashville, TN, USA
  • Volume
    19
  • Issue
    4
  • fYear
    2015
  • fDate
    Jul-15
  • Firstpage
    1362
  • Lastpage
    1374
  • Abstract
    Localizing the anterior and posterior commissures (AC/PC) and the midsagittal plane (MSP) is crucial in stereotactic and functional neurosurgery, human brain mapping, and medical image processing. We present a learning-based method for automatic and efficient localization of these landmarks and the plane using regression forests. Given a point in an image, we first extract a set of multiscale long-range contextual features. We then build random forests models to learn a nonlinear relationship between these features and the probability of the point being a landmark or in the plane. Three-stage coarse-to-fine models are trained for the AC, PC, and MSP separately using downsampled by 4, downsampled by 2, and the original images. Localization is performed hierarchically, starting with a rough estimation that is progressively refined. We evaluate our method using a leave-one-out approach with 100 clinical T1-weighted images and compare it to state-of-the-art methods including an atlas-based approach with six nonrigid registration algorithms and a model-based approach for the AC and PC, and a global symmetry-based approach for the MSP. Our method results in an overall error of 0.55 ± 0.30 mm for AC, 0.56 ± 0.28 mm for PC, 1.08 ± 0.66 in the plane´s normal direction, and 1.22 ± 0.73 voxels in average distance for MSP; it performs significantly better than four registration algorithms and the model-based method for AC and PC, and the global symmetry-based method for MSP. We also evaluate the sensitivity of our method to image quality and parameter values. We show that it is robust to asymmetry, noise, and rotation. Computation time is 25 s.
  • Keywords
    biomedical MRI; brain; feature extraction; image registration; image sampling; learning (artificial intelligence); medical image processing; neurophysiology; regression analysis; surgery; MRI scans; T1-weighted images; anterior commissure; atlas-based approach; automatic localization; coarse-to-fine models; functional neurosurgery; global symmetry; human brain mapping; image downsampling; image quality; learning-based method; leave-one-out approach; magnetic resonance imaging; medical image processing; midsagittal plane; multiscale long-range contextual feature extraction; nonrigid registration algorithms; parameter values; posterior commissure; random forests models; regression forests; stereotactic neurosurgery; Computed tomography; Feature extraction; Image resolution; Standards; Testing; Training; Vegetation; Anterior commissure (AC); anterior commissure,; midsagittal plane; midsagittal plane (MSP); posterior commissure; posterior commissure (PC); regression forests;
  • fLanguage
    English
  • Journal_Title
    Biomedical and Health Informatics, IEEE Journal of
  • Publisher
    ieee
  • ISSN
    2168-2194
  • Type

    jour

  • DOI
    10.1109/JBHI.2015.2428672
  • Filename
    7098323