DocumentCode :
494792
Title :
Transient NEMP field coupling with buried shielded cables
Author :
Sunitha, K. ; Thomas, M. Joy
Author_Institution :
Dept. of Electr. Eng., Indian Inst. of Sci., Bangalore, India
fYear :
2008
fDate :
26-27 Nov. 2008
Firstpage :
179
Lastpage :
184
Abstract :
The interaction of transient electromagnetic field due to an NEMP with buried cables has been studied in this paper. The cables studied were of two types: shielded as well as unshielded cables. Using transmission line analysis, the induced voltage and current are computed at the load end of the cable for different soil conductivities, different depths of burial of cable and for different lengths of the cable. Effect of shielding on the induced voltage on the cable inner conductor as well as the dependence of the induced voltage on the shield thickness are also studied.
Keywords :
cable shielding; electromagnetic coupling; electromagnetic fields; electromagnetic shielding; buried shielded cables; induced current; induced voltage; shielding effect; soil conductivities; transient NEMP field coupling; transient electromagnetic field; transmission line analysis; unshielded cables; Cable shielding; Cables; Conductivity; Couplings; Electromagnetic fields; Electromagnetic transients; Power system transients; Soil; Transmission lines; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Interference & Compatibility, 2008. INCEMIC 2008. 10th International Conference on
Conference_Location :
Bangalore
Print_ISBN :
978-81-903575-1-7
Type :
conf
Filename :
5154241
Link To Document :
بازگشت