Title :
Study on Surface Treatment of Double Grid Air Counter Sensor
Author :
Yuan Xiao-qing ; Shi Yi-kai
Author_Institution :
Sch. of Mechatron., Northwestern Polytech. Univ., Xi´an, China
Abstract :
In order to detect the microcrack of metal materials, a novel double grid air counter sensor was introduced. Starting with emission mechanism of low energy, ionic motion situation in the Double Grid Air Counter (DGAC) was analyzed, secondary electron emission was discussed, interaction between ion and inner wall of the counter and its effect on the counter was put forward, and treatment simulation graphs of counter inner surface plating different metals were given. The results showed that the counter plating gold could inhibit secondary electron and work accurately.
Keywords :
crack detection; exoelectron emission; microcracks; sensors; surface cracks; surface treatment; counter inner surface plating; double grid air counter sensor; ionic motion situation; metal materials; microcrack detect; secondary electron emission; surface treatment; treatment simulation graphs; Anodes; Automation; Counting circuits; Electron emission; Energy loss; Gold; Inorganic materials; Lattices; Mechatronics; Surface treatment;
Conference_Titel :
Measuring Technology and Mechatronics Automation, 2009. ICMTMA '09. International Conference on
Conference_Location :
Zhangjiajie, Hunan
Print_ISBN :
978-0-7695-3583-8
DOI :
10.1109/ICMTMA.2009.326