Experimental study of the interference caused by PLC transmission on HF bands
Author
Adebisi, Bamidele ; Stott, Jonathan ; Honary, Bahram
Author_Institution
Department of Communication Systems, Infolab21, South Drive, Lancaster University, LA1 4WA, United Kingdom
fYear
2006
fDate
18-21 July 2006
Firstpage
326
Lastpage
330
Abstract
With the growing deployment of PLC, EMC emissions are attracting great interest. In this paper, experimental study of the impact of emissions from indoor PLC systems on HF bands is carried out. Results from the measured radiated and conducted emissions are analysed in the frequency bands of 1–30MHz. These results show that the radiated field strength declines as the distance from a radiating source increases. Moreover, radiated field strength from a PLC network could be greater at places far away from the areas that benefit from the data. It is also shown that measured emissions do not meet all the specified limits.
Keywords
Broadband over Power Lines (BPL); Electromagnetic Compabitility (EMC) Standards; HF; Power Line Communications (PLC); Regulations;