• DocumentCode
    501869
  • Title

    Improving the balanced coaxial differential probe for high-voltage pulse measurements

  • Author

    Maloney, Timothy J. ; Cho, Dae-Hyung ; Poon, Steven S. ; Lisenker, Boris

  • Author_Institution
    Intel Corp., Santa Clara, CA, USA
  • fYear
    2001
  • fDate
    11-13 Sept. 2001
  • Firstpage
    396
  • Lastpage
    405
  • Abstract
    The balanced coaxial differential probe benefits from tuning of the probe and z-match inductances near the probe tip. Imbalances in the two channels can be assessed and minimized using a ferrite. The probe´s network analyzer spectrum is explained, with common mode resonance over the cable length related to the main source of error.
  • Keywords
    network analysers; network analysis; balanced coaxial differential probe; common mode resonance; high-voltage pulse measurement; network analyzer spectrum; probe tip; z-match inductance; Coaxial components; Probes; Pulse measurements;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium, 2001. EOS/ESD '01.
  • Conference_Location
    Portland, OR
  • Print_ISBN
    978-1-5853-7039-9
  • Electronic_ISBN
    978-1-5853-7039-9
  • Type

    conf

  • Filename
    5254940