• DocumentCode
    502575
  • Title

    Methods to remove anomalies from human body model pulse generators

  • Author

    Grund, E. ; Hernandez, M.

  • Author_Institution
    Oryx Instrum. Corp., Fremont, CA, USA
  • fYear
    2006
  • fDate
    10-15 Sept. 2006
  • Firstpage
    335
  • Lastpage
    342
  • Abstract
    Small anomalies found in pulses from HBM testers have been the subject of much recent research. Reported anomalies have been shown to adversely effect HBM testing. This paper reviews the cause of many anomalies and describes an HBM pulse generation system that eliminates or reduces these anomalies to negligible levels.
  • Keywords
    electrostatic discharge; integrated circuit testing; pulse generators; HBM pulse generation system; HBM testers; human body model pulse generators; small pulse anomalies; transmission line pulse testing; Biological system modeling; Humans; Pulse generation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium, 2006. EOS/ESD '06.
  • Conference_Location
    Anaheim, CA
  • Print_ISBN
    978-1-5853-7115-0
  • Type

    conf

  • Filename
    5256761