DocumentCode :
502575
Title :
Methods to remove anomalies from human body model pulse generators
Author :
Grund, E. ; Hernandez, M.
Author_Institution :
Oryx Instrum. Corp., Fremont, CA, USA
fYear :
2006
fDate :
10-15 Sept. 2006
Firstpage :
335
Lastpage :
342
Abstract :
Small anomalies found in pulses from HBM testers have been the subject of much recent research. Reported anomalies have been shown to adversely effect HBM testing. This paper reviews the cause of many anomalies and describes an HBM pulse generation system that eliminates or reduces these anomalies to negligible levels.
Keywords :
electrostatic discharge; integrated circuit testing; pulse generators; HBM pulse generation system; HBM testers; human body model pulse generators; small pulse anomalies; transmission line pulse testing; Biological system modeling; Humans; Pulse generation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Overstress/Electrostatic Discharge Symposium, 2006. EOS/ESD '06.
Conference_Location :
Anaheim, CA
Print_ISBN :
978-1-5853-7115-0
Type :
conf
Filename :
5256761
Link To Document :
بازگشت