• DocumentCode
    502578
  • Title

    Pre Pulse Voltage in the Human Body Model

  • Author

    Ashton, R.A. ; Worley, E.

  • Author_Institution
    White Mountain Labs., Phoenix, AZ, USA
  • fYear
    2006
  • fDate
    10-15 Sept. 2006
  • Firstpage
    326
  • Lastpage
    334
  • Abstract
    The pre pulse voltage present on low leakage HBM stress points before the HBM current pulse are found to be sensitive to device geometry, capacitance, resistive loading and velocity of approach both in simulated and real world events.
  • Keywords
    bioelectric phenomena; electrostatic discharge; integrated circuits; network synthesis; voltage measurement; HBM current pulse; capacitance; device geometry; human body model; low leakage HBM stress points; prepulse voltage; resistive loading; Biological system modeling; Capacitance; Circuit simulation; Discrete event simulation; Geometry; Humans; Relays; Solid modeling; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium, 2006. EOS/ESD '06.
  • Conference_Location
    Anaheim, CA
  • Print_ISBN
    978-1-5853-7115-0
  • Type

    conf

  • Filename
    5256764