Title :
Study on EMI phenomena for GMR/TMR head
Author :
Natori, S. ; Wada, T. ; Itou, Y. ; Sakata, H. ; Kataoka, K. ; Tanabe, H. ; Ohtsu, T.
Author_Institution :
Hitachi Comput. Peripherals Co., Ltd., Hitachi, Japan
Abstract :
ESD waveforms such as the Human Body Model (HBM), the Machine Model (MM), and the Charged-Device Model (CDM), are standard methods used to evaluate ESD sensitivity of parts. However, in recent years, there has been a growing concern about damaging GMR heads from Electro-Magnetic Interference (EMI). Since no standard method exists for EMI evaluation, it is important to develop one. In this paper, we studied a relatively easy method for comprehending the basic characteristics of EMI using the instruments that are widely used in conventional ESD evaluation.
Keywords :
electromagnetic interference; electrostatic discharge; giant magnetoresistance; magnetic heads; magnetoresistive devices; tunnelling magnetoresistance; EMI phenomena; ESD evaluation; GMR head; TMR head; electro-magnetic interference; giant magnetoresistive head; tunnelling magnetoresistive head; Biological system modeling; Electromagnetic interference; Electrostatic discharge; Electrostatic interference; Frequency; Giant magnetoresistance; Humans; Magnetic heads; Oscilloscopes; Switches;
Conference_Titel :
Electrical Overstress/Electrostatic Discharge Symposium, 2006. EOS/ESD '06.
Conference_Location :
Anaheim, CA
Print_ISBN :
978-1-5853-7115-0