• DocumentCode
    502654
  • Title

    Effect of GMR recording head resistance on human body and machine model ESD waveforms

  • Author

    Lai, Anthony Wai Yeun ; Wallash, Al

  • Author_Institution
    SAE Magnetic (HK) Ltd, SAE Tower, 38-42 Kwai Fung Crescent, Kwai Chung, N.T., Hong Kong, China
  • fYear
    2002
  • fDate
    6-10 Oct. 2002
  • Firstpage
    340
  • Lastpage
    344
  • Abstract
    The effect of the GMR sensor resistance on HBM and MM ESD current waveforms is studied. It is shown that the sensor resistance can have a significant impact on the peak current and waveform shape, especially for MM ESD testing. SPICE modeling results confirm the experimental data for HBM and MM. It is concluded that if the resistance between devices varies significantly, then reporting failure voltage alone can be misleading, since higher resistance devices will experience less current at the same voltage.
  • Keywords
    Biological system modeling; Circuit testing; Electrostatic discharge; Giant magnetoresistance; Humans; Immune system; Magnetic heads; Magnetic recording; Magnetic sensors; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    2002 Electrical Overstress/Electrostatic Discharge Symposium, 2002. EOS/ESD '02.
  • Conference_Location
    Charlotte, NC, USA
  • Print_ISBN
    978-1-5853-7040-5
  • Electronic_ISBN
    978-1-5853-7040-5
  • Type

    conf

  • Filename
    5267002