Title :
Impact of the CDM tester ground plane capacitance on the DUT stress level
Author :
Goeau, Cédric ; Richier, Corinne ; Salomé, Pascal ; Chante, Jean-Pierre ; Jaouen, Hervé
Author_Institution :
STMicroelectronics, Crolles, France
Abstract :
The CDM ground plane capacitance CGP is a key parameter for the tester modeling. From a test point of view, we show that the CDM test result depends on CGP, and thus of all parameters which influence it, like the ground plane size or the DUT package thickness. Then from a simulation point of view, we have to take into account CGP since this value defines the right voltage stress applied on the simulated circuit.
Keywords :
circuit simulation; electrostatic discharge; integrated circuit testing; CDM tester ground plane capacitance; DUT stress level; circuit simulation; tester modeling; Capacitance; Costs; Electrostatic discharge; IEC standards; Microelectronics; Performance evaluation; Pins; Power supplies; Stress; System testing;
Conference_Titel :
Electrical Overstress/Electrostatic Discharge Symposium, 2005. EOS/ESD '05.
Conference_Location :
Tucson, AZ
Print_ISBN :
978-1-58537-069-6
Electronic_ISBN :
978-1-58537-069-6