• DocumentCode
    503049
  • Title

    Biased-plate characterization of pulsed DC ionizers

  • Author

    Crowley, Joseph M. ; Ignatenko, Alexander ; Levit, Larry B.

  • Author_Institution
    Electrostatic Applic., Morgan Hill, CA, USA
  • fYear
    2003
  • fDate
    21-25 Sept. 2003
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    The operation of a pulsed DC air ionization system was studied in a side-by-side comparison using a charged-plate monitor (CPM) and a biased-plate monitor (BPM). When the pulse period is short compared to the decay time, both methods give equivalent results. When the pulse is not short, however, the CPM suffers from a random error on the order of the pulse period. In addition, the CPM method is quite sensitive to the motion of persons and other objects in its vicinity. Neither of these errors occurs with the BPM, which therefore provides a significantly faster way of adjusting pulsed DC ionizers.
  • Keywords
    clean rooms; discharges (electric); equivalent circuits; ionisation; biased-plate characterization; charged-plate monitor; equivalent electrical circuit; pulsed DC air ionization system; pulsed DC ionizers; random error; Current measurement; Delay; Electric resistance; Electric variables measurement; Electrical resistance measurement; Electrostatic discharge; Equivalent circuits; Ionization; Monitoring; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium, 2003. EOS/ESD '03.
  • Conference_Location
    Las Vegas, NV
  • Print_ISBN
    978-1-5853-7057-3
  • Electronic_ISBN
    978-1-5853-7057-3
  • Type

    conf

  • Filename
    5272012