• DocumentCode
    503370
  • Title

    A well-posed mathematical model of radiometer and its experimental embodiment with noise heterodyne

  • Author

    Sergienko, S.P.

  • Author_Institution
    Donetsk Nat. Univ., Donetsk, Ukraine
  • fYear
    2009
  • fDate
    14-18 Sept. 2009
  • Firstpage
    801
  • Lastpage
    802
  • Abstract
    A well-posed mathematical model of a radiometer with noise and monochromatic heterodynes is proposed. It is shown that a radiometer with a noise heterodyne operates more effectively than a radiometer with monochromatic heterodyne. A prototype of a radiometer is designed and built, which allows using a noise source as well as a sinusoidal source as heterodyne. The operative embodiment of a radiometer demonstrated an increase of sensitivity by 30 dB using a noise heterodyne.
  • Keywords
    noise; radiometers; experimental embodiment; monochromatic heterodyne; noise heterodyne; radiometer; sinusoidal source; well-posed mathematical model; Mathematical model; Radiometry; Tellurium; Zinc;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave & Telecommunication Technology, 2009. CriMiCo 2009. 19th International Crimean Conference
  • Conference_Location
    Sevastopol
  • Print_ISBN
    978-1-4244-4796-1
  • Type

    conf

  • Filename
    5292866